22 SCT Weight Transmitter Operator’s Manual

Soldered Jumper

For the output -10 +10 V and -5 +5 V the soldered jumper J7 must be closed:

• Remove the face plate of the instrument by removing the screws that attach

it to the little columns on the printed circuit board.

• On the circuit board, locate the jumper J7, situated above the 3 and 4

terminals at about mid board.

• Scrape away the solder from the jumper bay, until the copper underneath is

uncovered.

• Close the jumper short circuiting the bays, it is also recommended that a

small piece of copper wire without insulation or a leg wire be used to

facilitate the operation.

Analog Output Type Scale Corrections

Minimum and maximum values which can be set for the zero and full

scale corrections

The analog output may also be used in the opposite manner, i.e.
the weight setting that corresponds to the analog zero may be
greater than the weight set for the analog full scale. The analog
output will increase towards full scale as the weight decreases; the
analog output will decrease as the weight increases.

E.g.: analog output type having selected 0-10V
ANA 0 = 10000 ANA FS = 0
Weight = 0 kg

analog output = 10 V

Weight = 5000 kg

analog output = 5 V

Weight = 10000 kg

analog output = 0 V

Analog Output Type

Minimum Maximum

0–10 V

-0.150

10.200

0–5 V

-0.150

5.500

-10 +10 V

-10.300

10.200

-5 +5 V

-5.500

5.500

0-20 mA

-0.200

22.000

4-20 mA

-0.200

22.000

Note