Rice Lake SCT-10 User Manual
Page 26
22 SCT Weight Transmitter Operator’s Manual
Soldered Jumper
For the output -10 +10 V and -5 +5 V the soldered jumper J7 must be closed:
• Remove the face plate of the instrument by removing the screws that attach
it to the little columns on the printed circuit board.
• On the circuit board, locate the jumper J7, situated above the 3 and 4
terminals at about mid board.
• Scrape away the solder from the jumper bay, until the copper underneath is
uncovered.
• Close the jumper short circuiting the bays, it is also recommended that a
small piece of copper wire without insulation or a leg wire be used to
facilitate the operation.
Analog Output Type Scale Corrections
Minimum and maximum values which can be set for the zero and full
scale corrections
The analog output may also be used in the opposite manner, i.e.
the weight setting that corresponds to the analog zero may be
greater than the weight set for the analog full scale. The analog
output will increase towards full scale as the weight decreases; the
analog output will decrease as the weight increases.
E.g.: analog output type having selected 0-10V
ANA 0 = 10000 ANA FS = 0
Weight = 0 kg
analog output = 10 V
Weight = 5000 kg
analog output = 5 V
Weight = 10000 kg
analog output = 0 V
Analog Output Type
Minimum Maximum
0–10 V
-0.150
10.200
0–5 V
-0.150
5.500
-10 +10 V
-10.300
10.200
-5 +5 V
-5.500
5.500
0-20 mA
-0.200
22.000
4-20 mA
-0.200
22.000
Note