0 operation, 1 semi-automatic tare (net/gross), 2 preset tare (subtractive tare device) – Rice Lake SCT-10 User Manual

Page 36: Operation

Advertising
background image

32 SCT Weight Transmitter Operator’s Manual

3.0 Operation

3.1

Semi-Automatic Tare (Net/Gross)

The semi-automatic tare value is lost upon instrument power-off.

The semi-automatic tare operation is not allowed if the gross
weight is zero.

1. To capture tare and weigh in net mode (SEMI-AUTOMATIC TARE),

close the NET/GROSS input or press

for 3 seconds. The

instrument displays the net weight (zero) and the NET LED lights up.

2. To display the gross weight again, keep the NET/GROSS input closed

or press

for 3 seconds.

3. This operation can be repeated by the operator to allow the loading of

several products.

Press and hold

to display the gross weight temporarily. When

is released, the net weight will be displayed again.

3.2

Preset Tare (Subtractive Tare Device)

It is possible to manually set a preset tare value to be subtracted from the display

value provided that the P-tArE ≤ max capacity.

1. Press and hold

and

to display P-tArE, press

.

2. Press

or

until desired value is displayed, press

.

3. Press

to exit P-tArE.

4. After setting the tare value, go back to the weight display, the display

shows the net weight (subtracting the preset tare value) and the NET

LED lights up to show that a tare has been entered.

Press and hold

for 3 seconds to display the gross weight

temporarily. When

is released, the net weight will be

displayed again.

To delete a preset tare and return to the gross weight display:

1. Press hold

for 3 seconds or keep the NET/GROSS input (if any)

closed for the same length of time (3 seconds). The preset tare value is

set to zero. The NET LED is turned off when the gross weight is

displayed once again.

Note

TARE

TARE

Note

PRINT

PRINT

MENU

TARE

MENU

TARE

PRINT

MENU

0

ESC

Note

PRINT

PRINT

TARE

Advertising