28 SCT Weight Transmitter Operator’s Manual

2.7

Test

1. Press and hold

, then press

. CALIb will be displayed.

2. Press

or

until tEst is displayed, press

. The currently

programmed value is displayed.

3. Press

or

until desired parameter is displayed, press

.

4. For In and NU-CEL, current reading is displayed, press

.

For Out, press

until corresponding value of the out you want to

change is flashing, press

to change the value, press

.

5. Press

twice to exit set-up menu.

In 1
In 2

nE-LO *
(In 2
default)

(NET/GROSS): by closing this input for less than one
second, it performs a SEMI-AUTOMATIC TARE and the
display will show the net weight. To display the gross
weight again, hold the NET/GROSS input closed for 3
seconds.

2ErO *
(In 1
default)

By closing the input for less than one second, the
weight is set to zero (see Section 3.3 “Semi-Automatic
Zero (Weight Zero-setting For Small Variations)” on
page 33)
.

PEAH

With the input closed the maximum weight value
reached remains on display. Opening the input the
current weight is displayed.

PLC

Closing the input no operation is performed, the input
status may however be read remotely by way of the
communication protocol.

COntin

Closing the input for less than one second the weight is
transmitted via the serial connection according to the
fast continuous transmission protocol one time only
(only if contin is set in the item serial).

COEFF

When the input is closed the weight is displayed based
on the set coefficient (see Section 2.1.6 “Setting Units
of Measure” on page 30 an
d Section 2.1.7 “Display
Coefficient” on page 31),
otherwise the weight is
displayed.

*

- indicates default value.

Parameter

Choices

Description

Table 2-8. Output and Input Menu

MENU

0

ESC

TARE

PRINT

MENU

TARE

PRINT

MENU

MENU

TARE

PRINT

MENU

0

ESC