OPERATING INSTRUCTIONS

4-5

To access this mode, press START and RESET together, then at the prompt, key in the

desired number.

Programming

12

Programming cycles

27

Creation of Programs

45 Programming

motors

System Setup

118

Disable Machine

181

Resets controller – erases all memory

201

Language option (1 – Italian, 2 – English, 3 – German, 4 – Spanish, 5 – French)

205

16 or 24 outputs

207 Maximum

RPM

209

Temperature Hysterisis (min 1 deg, max 10 deg) Default is 3 deg.

210

Display temperature in degrees C

211

Display temperature in degrees F

212 Maximum

water

level

that

can be set (10 – 100 cm.)

213

Minimum water level for heating (2 – 30 cm.)

214

Display number of hours of operation

215

Display total number of washes

216

Display number of washes since the last maintenance

217

Reset maintenance request

218

Display and set number of washes until maintenance request

219

Spin slow down time (40 – 200 sec)

220

Erases Programs and cycles

221

Copy from control to memory card

222

Copy from memory card to control (only programs and cycles)

223

Copy from memory card to control (programs, cycles, and parameters)

225

Disables Advance Key

230

Maximum water level allowed during spin (2 – 60 cm.)


Highlighted items are safety related and should not be changed.

Do not alter these values without consulting a qualified technician.


Programming

Programming the WC03 takes place on three levels:

1.

Programming motors (45)

Allows 15 different operating modes to be created for each mode, the clockwise rotation time,

the counterclockwise rotation time and the pause time can be programmed.

2.

Programming the cycles (12)

For each sequence of steps, creates a sequence of events in which various functions can be

activated or deactivated (drain, cold fill, spin, etc.). Going from one step to another may require
reaching a water level or temperature, or a time value. There are five different programmable cycle

Advertising