TROUBLE SHOOTING

7-14

9.

“dbH” Overheat protection for barking resistor

Problem

Thermal protection for braking resistor activated.

Possible Causes

What to Check and Suggested Measures

1. Braking load was too

heavy.

Recalculate the relation between the braking load and braking
capacity.
→ Lighten the braking load.
→ Reconsider the braking resistor in order to improve braking

ability. Resetting the data of function codes F50 and F51 is
also required.

2. The deceleration time was

too short.

Recalculate the required deceleration torque and time from the
moment of inertia for the load and the deceleration time.
→ Increase the deceleration time (F08, E11, and H54).
→ Reconsider the braking resistor in order to improve the braking

ability. Resetting the data of function codes F50 and F51 is
also required.

3. Incorrect values have been

set for the data of function
codes F50 and F51.

Check the braking resistor specifications.
→ Reconsider and change the data of function codes F50 and

F51.

NOTE:

The inverter does not detect the overheating alarm of a braking resistor by
monitoring its surface temperature, but by monitoring its load magnitude. Therefore,
even if the surface temperature itself does not rise, the alarm may be detected if the
resistor is used more frequently than the set data of function codes F50 and F51. If
you use the resistor to the limit of its capacity, you must adjust the data of function
codes F50 and F51 while checking the surface temperature of the resistor.

10. “OL1” Electronic thermal overload relay

Problem

Electronic thermal function for motor overload detection activated.

Possible Causes

What to Check and Suggested Measures

1. Load was too heavy.

Measure the output current.
→ Lighten the load (e.g. lighten the load before overload occurs

using the overload early warning (E34).

2. The acceleration /

deceleration time was too
short.

Check that the motor generates enough torque for acceleration /
deceleration, This torque is calculated from the moment of inertia
for the load and the acceleration / deceleration time.
→ Increase the acceleration / deceleration time (F07, F08, E10,

E11 and H54).

3. The characteristics of

electronic thermal did not
match those of the motor
overload.

Check the motor characteristics.
→ Reconsider the data of function codes P99, F10 and F12.
→ Use an external thermal relay.

4. Activation level for the

electronic thermal relay
was inadequate.

Check the continuous allowable current of the motor.
→ Reconsider and change the data of function code F11.