OPERATING INSTRUCTIONS

4-18

After power is applied to the machine, and the internal diagnostics are complete, the machine is
ready for a program to be chosen. The display will show:


Using the keypad, type the number of the program you wish to run followed by the ENTER key.
The display will change to show the fist cycle of the selected program:


Press START to execute the program, or RESET to return to program selection. While the
program is executing, the display shows the current segment of the program, and the ending
condition of the segment. See the following examples:

Level

If the end requirement of the segment (cycle) is a particular water level, the display will show:

cm 12 is the actual water level in the machine (12 centimeters). Pressing the LEVEL key shows,
for 3 seconds, the required value to advance. If INC or DEC is pressed, you can temporarily modify
the value for the current step. Pressing TEMP allows you to see the current temperature of the
water. Pressing the TIME key shows the watch dog timer (WDT) value for the current step.

Temperature

If the end requirement of the segment is a particular temperature, the display will show: where
35C is the actual temperature of the wash solution.


By pressing TEMP the display will change, for 3 seconds, show the required step temperature for
advance. Pressing INC or DEC allows modification of the value for the step. Pressing LEVEL
allows you to see the current water level. Pressing the TIME key shows the watch dog timer
(WDT) value for the current step.

Time

If the end this case, the display shows: the remaining time left in the step.


INC and DEC allow you to add or subtract minutes for the current cycle. TEMP allows you to view
the current water temperature, and LEVEL shows the current water level.

NOTE:

During heating, fill and drain phases, the WDT (watch dog timer) is activated. If the
phase does not complete before the timer expires, an alarm will be displayed
indicating that the particular phase did not complete within the maximum time
allowed.


PRWH 1 EXECUT.?

RINSE1 LVL = cm 12

WASH3 TEMP = 35 C

PROGRAMN._

RINSET1 T =2m 30s