205

16 or 24 relay output.

207 Maximum

RPM.

209

Temperature hysterisis (1 – 10 degrees C). 3 degrees C is default.

210

Temperature displayed in degrees C.

211

Temperature displayed in degrees F.

212

Maximum water level (10 -100cm).

213

Minimum water level for heating (230cm).

214

Display number of hours in operation.

215

Display total number of programs run.

216

Display number of wash programs run since last maintenance request.

217

Reset maintenance request.

218

Display and set the number of washes between maintenance requests.

219

Coast down safety timer. DO NOT MODIFY!

220

Deletes all programs and cycles from memory.

221

Copy from control to the memory card.

222

Copy from memory card to the control (programs and cycles only).

223

Copy from memory card to the control (programs, cycles and parameters).

225

Disables the ADVANCE key.

230

Maximum water level allowed during spin DO NOT MODIFY!


Maintenance Request

It is possible to set a number of wash programs to execute, following which the machine will call
for maintenance:


The message appears at the start of a program, and is repeated at the beginning of each wash
program until reset by a qualified service technician.

Disable the Machine

Function 118

Upon entering this function, the machine will not operate. The power must be cycled

(turned off, then back on) for the function to activate. Upon power up, the display will show:


To re – enable the machine, type 118 at prompt. START + RESET are not needed.