B&C Technologies SA Series Industrial User Manual

Page 45

Advertising
background image

OPERATING INSTRUCTIONS

4-23

Change Language

Function 201

The control can display in 5 different languages. To change the language, use function 201.

Upon entering the function, the display changes to:


Type the number which corresponds to your language, followed by ENTER:

1.

Italian

2.

English

3.

German

4.

Spanish

5.

French


16 or 24 Relays

Function 205

Each time function 205 is entered, the controller toggles between 16 and 24 relay setup. After

entering 205, the display shows the current mode.

Maximum Spin Speed

Function 201

This function allows you to display or modify the maximum spin speed. Upon entering the

function, the display will show the current value. To exit without changing, press RESET. If you
wish to change the value, press ENTER, type the new value, and press ENTER again. If the value
is within the acceptable range, the display will show YES. Otherwise, the display will show NO.

Temperature Hysterisis

Function 209

This function sets the allowed temperature variation parameter. The default value is 3

degrees. If you wish to change the value, press ENTER, key in the new value (1 – 10 degrees C),
then press ENTER again to confirm. To exit without changing, press RESET.

Temperature Display

Function 210

Function 211

During program execution, the temperature may be displayed in degrees Fahrenheit or

degrees Centigrade. For degrees F, enter function 211. For degrees C, enter function 210. Please
note that this is for display only. Programming is always done in degrees C. See the handy
conversion chart in the back of this manual.

Maximum Water Level

Function 212

This function allows display and modification of the maximum programmable water level.

To change the value, press ENTER, type in the new value, and press ENTER again to confirm. To

Lingua No.

Advertising