Troubleshooting

Frequently Asked Questions

Category

Trouble

Cause

Action

Received light
intensity display

The received light intensity is incon-
sistent. How can it be stabilized?

It may be affected by vibration, ther-
mal characteristics caused by ther-
mal changes, or the state of the
workpiece surface, etc.

• Review the installation environment.
• The received light intensity can be stably dis-

played at 100.0 by using the preset function.

"Preset Function" (page 3-6)

• When using the DATUM1/2 mode, the set value

and received light intensity are both calibrated to
maintain a set ratio.

"Detection Mode" (page 4-8)

The received light intensity is too
low. How can it be increased?

This may be the result of a long
detection distance. When using the
reflective model, the intensity of the
light reflected from the workpiece
may be low, or there may be con-
tamination. When using the thru-
beam model or retro-reflective
model, the beam axis may be devi-
ated, etc.

• Review the installation environment and detec-

tion distance.

• The received light intensity value can be

increased by raising (delaying) the power mode.

"Power Modes" (page 4-4)

• The apparent received light intensity can be

increased 4-fold by using the light intensity
expansion setting.

"Display Gain" (page 4-32)

The received light intensity remains
unchanged from 4095 or 9999 even
if a workpiece is placed for detec-
tion.

The received light intensity has
become too large.

• Extend the detection range.
• Lower the light emission level and the received

light intensity.

"Light emission/Received light intensity

adjustment (Saturation Canceling)" (page 3-18)

"Adjusting Light Emission/Received Light

Intensity (Attenuation)" (page 4-20)

When used under extremely short
conditions of the detection range,
the received light intensity
decreases.

Screen
display

Nothing is displayed.

Eco (

ALL

) mode is selected.

• Disable the Eco function.

"Power Save" (page 4-31)

The power is cut off or the power
cable is disconnected.

• Disable the Eco function.

"

-

" scrolls from left to right on the

display

Eco (

FuLL

) mode is selected.

• Disable the Eco function.

"Power Save" (page 4-31)

The sleep mode is enabled by the
external input.

• Turn the external input OFF, or select a mode

other than sleep mode transition input with the
external input function.

"Sleep function" (page 4-19)

Output
operation

The received light intensity at which
the output turns ON and turns OFF
is slightly different.

The output timer is set.

• Check the output timer setting.

"Output Timer" (page 4-7)

Hysteresis

• A slight hysteresis is set to prevent chattering in

the output. If this level of received light intensity
is notable during detection, the detection toler-
ance may be low. Please review the detection
details.

Advertising