Operating principles of the preset function – KEYENCE FS-N10 Series User Manual

Page 75

Advertising
background image

4-4 Display Settings (diSP)

4

Set

tings
f

o

r

Ad
v

an
ced F

u

nct
ion
s

4-29

- Digital Fiber Sensor FS-N10 Series User's Manual -

Operating principles of the preset function

(Current received light intensity is 3300 in this example.)

Preset input is used to register the
light intensity as "

100.0

".

The actual received light intensity (3300)
is set to "110%" and all actual received
light intensities exceeding "100%" are
displayed as "

100.0

".

When light intensity falls below "100%", a
value lower than "

100.0

" is displayed.

(The percentage value "110%" (i.e., the
saturation level) at the time of registration
can be any value between 100 and
200%.)

"Preset Saturation Function" (page 4-

28)

If the displayed light intensity falls below
"

100.0

", the preset input can be per-

formed again to restore stable detection.
If light intensity is not displayed as "

100.0

"

after preset input, the sensor amplifier is not
in stable detection condition.

Even when the maximum sensitivity preset function or full auto preset func-
tion is used, the preset saturation level setting function operates based on
the "

100.0

" point.

90.0

100.0

110.0

0

Received light intensity

All values in this
range are 100.0.

4095

3300
3000
2700

(After preset input)

2970
2700

Received light intensity

4095

3300

(After another preset input for correction)

100.0

110.0

0

All values in this
range are 100.0.

Reference