Display gain, Display gain -32 – KEYENCE FS-N10 Series User Manual

Page 78

Advertising
background image

4-5 System Settings (SYS)

4

Set

tings
f

o

r

Ad
v

an
ced F

u

nct
ion
s

4-32

- Digital Fiber Sensor FS-N10 Series User's Manual -

Received light intensity can be increased 4 times without sacrificing response time.

The maximum received light intensity value which can be displayed differs according
to the power mode setting and display screen.
The maximum received light intensity values which can be displayed are shown
below.

"Power Modes" (page 4-4)

"Extension display" (page 4-24)

• This function is not supported in the

hSP

(HIGH SPEED) mode and

the light intensity expansion setting screen is not displayed.

• When the preset function is used in DATUM1 or DATUM2 mode,

correctible values are limited to 200.

Display Gain

Refer to page 4-2 "System Settings (SYS)" for setting methods.

Display

Function

Std

(Standard)

Normal light intensity display (Default)

FuLL

(Full)

Full light intensity display (Hysteresis increases 4 times)

Display

screen

Display

gain

HIGH

SPEED

FINE

TURBO SUPER

ULTRA

MEGA

Normal dis-

play

Std

4095

4095

4095

8190

9999

9999

FuLL

-

9999

9999

9999

9999

9999

StdE

(Extension

display)

Std

4095

4095

4095

8190

32760

65504

FuLL

-

16380

16380

32760

65504

65408

Point