4-3 Detection Settings (Func)

4

Set

tings
f

o

r

Ad
v

an
ced F

u

nct
ion
s

4-22

- Digital Fiber Sensor FS-N10 Series User's Manual -

The analog output can be automatically scaled so that the 5 V is output in respect to
the received light intensity "

100.0

". This function is used simultaneously with the

various preset function. This function is useful when frequently using the preset
function as the analog output can be constantly sequenced with the "

.0

to

100.0

"

display, etc.
* Not available for the FS-N10 Series shipped before March 10, 2011.

1

When received light intensity is dis-
played, press and hold the [MODE] but-
ton, [SET] and

button

simultaneously for 3 seconds or more.

ProG YES

or

ProG no

is displayed.

2

Press the [MODE] button once.

3

Using the

button, select

Pr-A

Std

to not change the analog upper limit
value when the preset function is exe-
cuted, and select

Pr-A PrSt

to change

the analog upper limit value sequen-
tially when the preset function is exe-
cuted. Then, hold down the [MODE] button.

When "

Std

" (default) is set, the analog output upper limit will not change

even if the various preset function is used.

Analog scaling mode (FS-N11MN only)