3-6 Loading the Recommended Settings (Recipe Function)

3

Ba
sic
Oper

ati
on

3-20

- Digital Fiber Sensor FS-N10 Series User's Manual -

* Not available for the FS-N10 Series shipped before March 10, 2011.

Refer to "List of Recipe Function Settings" (page 6-7) for the details on the
items set with recipe loading.

List of Recipes and Recommended Fiber Units

Recipe

Recommended

units

Description

Fall detection
(

r-1 FALL

)

Thrubeam model

To detect a falling workpiece.
The falling edge of the received light intensity is
detected, and output as one-shot.
The received light intensity hold value can be con-
firmed by pressing the [MODE] button twice on the
output 1 screen.

Percentage
calibration
(

r-2 SEtP

)

Thrubeam model

Retro-reflective

model

To use the external input and periodically compen-
sate for the reduction in received light intensity due
to contamination on sensor head face.
A decrease in the light-ON mode's received light
intensity can be detected and output to an external
source by using the 2-output type's output 2.

Reflective
background
cancellation
(

r-3 0SEt

)

Reflective model

To use the external input and "

0

" the light intensity

received without a workpiece present.
The background received light intensity is set as 0
even when calibrating with the buttons on the display.
(Zero Shift calibration)

Full light
intensity
(

r-4 MEGA

)

Reflective model

To 0 the lower of level received light intensity values
in order to display higher values of received light
intensity.
The display can be extended up to 5 digits by press-
ing the [MODE] button twice on the output 1 screen.

Area detection*
(

r-5 ArEA

)

Area model

(FU-E11/E40)

This is recommended when outputting within a spe-
cific received light intensity range. When the [SET]
button is pressed once at the reference received light
intensity, the upper/lower setting value limits will be
set at ±10% from the reference received light inten-
sity.

0-DATUM*
(

r-6 0dtM

)

Retro-reflective

model

This is recommended when detecting a transparent
workpiece. The received light intensity at the state
with no workpiece is set as "

.0

", and the displayed

value is increased as the amount of light blocked by
the workpiece increases.
When the [SET] button is pressed or when calibrated
with external inputs, the received light intensity -5%
at that point is set as the setting value.

Reference