5-1 Specifications

5

Sp
eci
fic

at

io

ns

5-3

- Digital Fiber Sensor FS-N10 Series User's Manual -

*1

For M8 connector type, cable length must be 30 m or less.

*2

Increased by 100 mW (4.0 mA) for HIGH SPEED mode.

*3

One or two units connected: -20 to +55 °C; 3 to 10 units connected: -20 to +50 °C,
11 to 16 units connected: -20 to +45 °C. When using 2-output type, one unit is counted as two units.
All temperature specifications are for when the unit is mounted on a DIN rail; and installed on metal frame.

2-Output Type

Type

2-Output Type

Input/Output configuration

Cable

M8 connector

*1

Main unit/Expansion Units

Main unit

Expansion unit

Main unit

Expansion unit

Models

NPN

FS-N13N

FS-N14N

-

-

PNP

FS-N13P

FS-N14P

FS-N13CP

FS-N14CP

Number of
input/out-
put

Control output 2-output

2-output

2-output

2-output

Monitor output
(1-5V)

-

-

-

-

External input

1-input

1-input

-

-

Light source LED

Red 4-element LED (Wavelength: 630 nm)

Response time

50us(HIGH SPEED)/250us(FINE)/500us(TURBO)/1ms(SUPER)/4ms(ULTRA)/16ms(MEGA)

Output toggle

Light-ON/Dark-ON toggle

Timer functions

Timer OFF/OFF delay/ON delay/One-shot

Input/Out-
put specifi-
cations

Control output
(NPN)

NPN open collector 24 V or less, 2-output maximum 100 mA or less (used stand-alone)/20 mA or

less (multiple connections)

Residual voltage: 1V or less

Control output
(PNP)

PNP open collector 24 V or less, 2-output maximum 100 mA or less (used stand-alone)/20 mA or

less (multiple connections)

Residual voltage: 1V or less

External input

Input time: 2 ms(ON) / 20 ms(OFF) or more. 25 ms(ON/OFF) or more only when toggled to

external calibration input

Expansion units

Up to 16 units can be connected (total connection of 17 units including the main unit); 2-output

type is treated as 2 units, however.

Protection circuit

Protection against reverse power connection, output overcurrent and output surge

Number of interference preven-
tion units

Up to 16 units can be connected, but may differ depending on the power mode.

0 for HIGH SPEED; 4 for FINE and 8 for TURBO/SUPER/ULTRA/MEGA

(These numbers double when "Double" is selected.)

Rating

Supply voltage

DC12-24V±10%, ripple (P-P) 10% or less

Power consumption
(NPN output type)

Normal: 900 mW or less (36 mA or less at 24 VDC; 48 mA or less at 12 VDC)

*2

ECO ON (All): 800 mW or less (32 mA or less at 24 VDC; 39 mA or less at 12 VDC)

*2

ECO Full: 470 mW or less (19 mA or less at 24 VDC; 23 mA or less at 12 VDC)

Power consumption
(PNP output type)

Normal: 1050 mW or less (42mA or less at 24 VDC; 56mA or less at 12 VDC)

*2

ECO ON (All): 950 mW or less (38mA or less at 24 VDC; 47mA or less at 12 VDC)

*2

ECO Full: 600 mW or less (24mA or less at 24 VDC; 29mA or less at 12 VDC)

Environ-
ment resis-
tance

Operating ambient
luminance

Incandescent lamp: 20,000 lx or less; solar light: 30,000 lx or less

Operating ambient
temperature

-20 °C to +55 °C (no freezing)

*3

Operating ambient
humidity

35 to 85% (no condensation)

Vibration resistance

10 to 55 Hz Compound amplitude 1.5 mm, two hours for each of X, Y and Z axes

Shock resistance

500m/s

2

, 3 times for each of X, Y and Z axes

Case material

Both main unit and cover material: Polycarbonate

Case dimensions

H30.3mm×W9.8mm×L71.8mm

Mass

Approx. 80g

Approx. 70g

Approx. 22g

Approx. 22g