3-3 Adjusting Sensitivity

3

Ba
sic
Oper

ati
on

3-8

- Digital Fiber Sensor FS-N10 Series User's Manual -

This function calibrates the reference state to "

.0

" and the state at which the received

light intensity is slightly higher as "

100.0

".

This function is useful with the reflective model to detect while using the background
as a reference.
* Not available for the FS-N10 Series shipped before March 10, 2011.

Enabling the maximum sensitivity preset function

1

When no workpiece is present for the
reflective model, or when a workpiece
is present for thrubeam model/retro-
reflective model, press and hold the
[PRESET] button for 3 seconds or more
while the PST indicator is OFF.
Release the button when "

Auto

" flashes.

Calibration is complete after the setting
value flashes momentarily, and then stops
(lights up).
The PST indicator lights in green, and the
setting value is set to "

50.0

".

• When the amount of the light received is in saturated state (at a

value higher than at the time of extended display on page 4-30),
maximum sensitivity preset function cannot be implemented.
("

---- ----

" is indicated when operating 1.)

"Light emission/Received light intensity adjustment (Saturation

Canceling)" (page 3-18)

Disabling the maximum sensitivity preset function

When the PST indicator is lit, press and hold the [PRESET] button.

• The PST indicator turns off, indicating that the maximum sensitivity preset func-

tion has been disabled.

Maximum Sensitivity Preset Function

Workpiece

Setting value

Setting value

Thrubeam Model/Retro-reflective Model

Reflective Model

Received light intensity

Received light intensity

No workpiece

With workpiece

No workpiece*

With workpiece*

1

1

Saturation point

"

100.0

"

"

50.0

"

"

.0

"

"

100.0

"

"

50.0

"

"

.0

"

Saturation point

*

Where detection occurs on a target having a background, the maximum sensitiv-
ity setting ignores the background. Maximum sensitivity setting is not available if
the background is more reflective than the workpiece.

Point