4-3 Detection Settings (Func)

4

Set

tings
f

o

r

Ad
v

an
ced F

u

nct
ion
s

4-12

- Digital Fiber Sensor FS-N10 Series User's Manual -

• When the received light intensity stays higher than a given warn-

ing level, the received light intensity correction stops and the DTM
indicator flashes.

"Changing the warning output level" (page 4-13)

• The light intensity correction stops if the raw received light inten-

sity drops below 50 (200 when the light intensity expansion setting
is set to

Full

). The raw received light intensity can be confirmed by

pressing the [MODE] button for longer than 3 seconds on the Basic
screen.

"Display Gain" (page 4-32)

• By pressing the [PRESET] button,

the current value (received light
intensity) can be forcibly calibrated
to "0". Calibration is completed
when the current value stops flash-
ing. (At this time, the setting value is internally calibrated so that the
received light intensity and setting value ratio stay constant.)

• You can also set the interval for executing correction, and/or the level of

received light intensity change for issuing a warning.

"Adjusting the correction interval" (page 4-12)

"Changing the warning output level" (page 4-13)



Adjusting the correction interval

A desired correction interval can be selected from the 3 levels:

LEv1

(LEVEL1) is recommended.

Point

Reference

Refer to page 4-2 "Detection Settings (Func)" for setting methods.

Power mode

LEv1

(LEVEL1)

LEv2

(LEVEL2)

LEv3

(LEVEL3)

HIGH SPEED

4.4 s

547.2 ms

34.2 ms

FINE

13.1 s

1.64 s

102.4 ms

TURBO/SUPER/ULTRA/MEGA

26.2 s

3.27 s

204.8 ms