6-5 Index

6-14

- Digital Fiber Sensor FS-N10 Series User's Manual -

6

Appen

di

x



Basic Settings

…(page 4-4)



Detection Settings (Func)

…(page 4-7)



Display Settings (diSP)

…(page 4-23)



System Settings (SYS)

…(page 4-30)

MODE

MODE

MODE

MODE

StG-
StG-
StG-

SET

1234

1234
1234
1234
1234
1234

Std

SEtP
OSEt

END

FuNc
DiSP

SYS

SET
SET

MODE

Press and hold for 3 seconds or more

FINE mode

TURBO mode

SUPER mode

ULTRA mode

MEGA mode

HIGH SPEED mode

Normal sensitivity setting method

Percentage Calibration*

1

Zero-shift calibration

Settings complete

Go to detection setup mode

Go to display setup mode

Go to system setup mode

Return to normal display

Fine

TurB
SuPR
ULTR
MEGA

hSP

…(page 4-4)

…(page 4-5)

…(page 4-6)

…(page 4-4)

…(page 4-4)

…(page 4-4)

…(page 4-4)

…(page 4-4)

…(page 4-4)

MODE

7

Settings complete

Go to display setup mode

Go to system setup mode

Return to detection
setup mode

Normal (light intensity)
detection mode

DATUM1 mode *

3

Timer OFF

Off-delay timer *

2

On-delay timer *

2

One-shot timer *

2

DATUM2 mode *

3

Area detection mode

Rising Edge Detection Mode

Falling Edge Detection Mode

External input off

External calibration input

Preset input

Zero shift input

Reset input

Light transmission OFF input

Pause function *

4

Sleep function

Return to normal display

Adjusting light emission/received light
intensity (Attenuation)

*5

8

Analog scaling

*6

Alternate
display

(page 4-7)

(page 4-8)

(page 4-9)

…(page 4-14)

…(page 4-16)

…(page 4-16)

(page 4-17)

(page 4-17)

(page 4-17)

(page 4-17)

(page 4-17)

(page 4-17)

(page 4-18)

(page 4-19)

(page 4-7)

(page 4-7)

(page 4-7)

…(page 4-21)

(page 4-11)

(page 4-20)

Normal display method

Reverse display

Settings complete

Go to system setup mode

Go to detection setup mode

Return to display setup mode

Sub-display off

Extension display

Bar display

Excess gain (%) display

Light intensity hold display *

9

Excess gain hold (%) display *

9

L-on / D-on display

Disable the saturation of the
Preset function

Enable the saturation of the
Preset function *

10

Return to normal display

…(page 4-23)

…(page 4-23)

…(page 4-23)

…(page 4-24)

…(page 4-24)

…(page 4-25)

…(page 4-25)

…(page 4-27)

…(page 4-27)

…(page 4-28)

…(page 4-28)

*11

Settings complete

Go to detection setup mode

Go to display setup mode

Return to system setup mode

Normal operation

Twice the number of
interference-prevention units as

STD

(response time 2 times slower)

Disable Eco Function

Enable Eco Function

Reduce power consumption
(response time 4 times slower)

Disable common key operations

Enable common key operations

APC function is disabled

APC function is enabled

Standard current value display

Maximum current value display
(4 times hysteresis)

Return to normal display

…(page 4-31)

…(page 4-31)

…(page 4-32)

…(page 4-32)

…(page 4-33)

…(page 4-33)

…(page 4-34)

…(page 4-34)

…(page 4-31)

…(page 4-30)

…(page 4-30)

List

o

f set
tings

Advertising