4-3 Detection Settings (Func)

4

Set

tings
f

o

r

Ad
v

an
ced F

u

nct
ion
s

4-18

- Digital Fiber Sensor FS-N10 Series User's Manual -

Pause function

During signal input, the output can
be locked in a desired state
regardless of received light input.
There are 3 selections of output
status that can be locked with the
pause function.

Refer to page 4-2 "Detection Settings (Func)" for setting methods.

Display

Function

oFF

The output is locked in OFF state during signal input. (Default)

on

The output is locked in ON state during signal input.

KEEP

The output is locked in its existing state when a signal is received
from the external input.

Signal input

Received light intensity

Pause OFF

L-on

Pause ON

Pause KEEP

Signal input

Thrubeam model

OFF

ON

Output

OFF

ON

Output

OFF

ON

Output

Advertising