6 2-output settings (), Detection mode for output2, Output settings – KEYENCE FS-N10 Series User Manual

Page 81: Detection mode for output2 -35, Output settings ( )

Advertising
background image

4

Set

tings
f

o

r

Ad
v

an
ced F

u

nct
ion
s

4-35

- Digital Fiber Sensor FS-N10 Series User's Manual -

4-6

2-output Settings (

)

*

This function is only available for the 2-output type models (FS-N13

/ N14

).

*1 If output 2 is set to

Std

, the DATUM1, DATUM2, area detection, and edge detection

modes are disabled in output 2.

*2 You can select the

USEr

(user reset) or

Auto

(auto reset) resetting methods after

outputting the limit setting under the following restriction:
- If output 1 is set to the DATUM1 mode or DATUM2 mode when

LiMt

is selected,

the detection will be performed with the value prior to DATUM calibration.

- If output 1 is set to the area detection mode or edge detection mode,

LiMt

can-

not be selected with output 2.

Detection Mode for Output2

Refer to page 4-3 "2-output Settings (

)" for setting methods.

Display

Function

Std

(Standard)

*1

Received-light intensity judgment mode (usual mode)
(Default)

LiMt

(Limit)

*2

Limit setting output mode (Output 2 turns on if received
light intensity for output 1 decreases).

"Limit setting output mode" (page 4-36)

ALrt

(Alert)

Warning output mode (Output 2 turns on when an error
occurs).

"Warning output mode" (page 4-37)