Maximum sensitivity calibration, Maximum sensitivity calibration -12 – KEYENCE FS-N10 Series User Manual

Page 34

Advertising
background image

3-3 Adjusting Sensitivity

3

Ba
sic
Oper

ati
on

3-12

- Digital Fiber Sensor FS-N10 Series User's Manual -

This sensitivity setting method is useful if the received light intensity is reduced by
dust or dirt.
The setting value is calibrated to be slightly than the light intensity received when it is
determined.

1

When a workpiece is absent for the
reflective model, or when a workpiece
is present for the thrubeam model/
retro-reflective model, press and hold
the [SET] button for 3 seconds or
more.
Release the button when "

SEt

" flashes.

Calibration is complete after the setting
value flashes momentarily, and then stops
(lights up).

Press the

button to adjust the setting

value.

When performing two-point calibration on channel 2 of the 2-output type,

set the channel switch to "

".

Maximum Sensitivity Calibration

Workpiece

Reference

Setting value

Setting value

Thrubeam Model/Retro-reflective Model

Reflective Model

Received light intensity

Received light intensity

No workpiece

With workpiece

No workpiece*

With workpiece*

1

1

*

Where detection occurs on a target having a background, the maximum sensi-
tivity setting ignores the background. Maximum sensitivity setting is not avail-
able if the background is more reflective than the workpiece.