Quick Reference

The main setting operations are explained according to purpose. Refer to Chapter 4
for information on advanced function settings and explanations not given below.

Purpose

Description

Operation procedures

Reference

page

Swiching the

output

1

Swiching the output. (L-on/D-on)

1. Press the [MODE] button.

2. Switch with the

(

) button.

3-4

Adjusting the

sensitivity and
integrating the

display to "

100.0

"

and "

.0

"

2

Set the current received light intensity
to "

100.0

". (Preset)

Press the [PRESET] button while the PST
indicator is OFF.

3-6

3

When preset is valid, register the
received light intensity "

.0

".

(Work-preset)

*

After step 7, press the [PRESET] button +

button in the state to be set as "

.0

".

3-7

4

Set the received light intensity slightly
higher than when the setting was
made, to "

100.0

". (Maximum sensitivity

preset)

*

While the PST indicator is OFF, press and hold
the [PRESET] button. Reflective model: When
no workpiece is present. Thrubeam/Retro-
reflective model: When a workpiece is present.

3-8

5

Automatically register "

100.0

" and "

.0

"

when workpiece passes by. (Full Auto

preset)

*

Press and hold the [PRESET] button while the
PST indicator is OFF.

3-9

6

Cancel the various preset functions.

Press and hold the [PRESET] button.

3-6

Adjusting the

sensitivity

7

Set the setting value at the midpoint
between the received light intensity
values when a workpiece is present
and absent. (2-point calibration)

1. Press the [SET] button once when a work-
piece is present.
2. Press the [SET] button once when no work-
piece is present.

3-11

8

Set the setting value slightly higher
than the received light intensity value
at which the setting was made. (Maxi-
mum sensitivity calibration)

Reflective model: Press and hold the [SET] but-
ton when no workpiece is present. Thrubeam/
Retro-reflective model: Press and hold the
[SET] button when a workpiece is present.

3-12

9

Set the setting value automatically
when a workpiece is passing through.
(Full auto calibration)

Press and hold the [SET] button while the
workpiece passes through.

3-13

10

Set the setting value to the base point
where the workpiece is positioned.
(Positioning calibration)

1. Press the [SET] button once when no work-
piece is present.
2. Press and hold the [SET] button at the posi-
tioning point.

3-14

11

Finely adjust the setting value directly.

Press the

(

) button.

1-4

Shifting the

received light

intensity to "

0

"

12

Set the current display to "

0

". (Zero

shift)

Press the [PRESET] button +

button when

the PST indicator is OFF.

3-16

13

Cancel the zero shift function.

Press and hold the [PRESET] button.

3-16

Need to prevent

the received light

intensity from

becoming satu-

rated.

14

Automatically adjusts to appropriate
light emission and light receiving sen-
sitivity.

Briefly press [MODE] + [SET] buttons with the
amount of received light in maximum-saturated
condition.

3-18

1

2

Manual button

[MODE]
button

Power select switch
(1-output type))

[PRESET]
button

[SET] button

Operation indicator

(1-output/Zero line type)

DTM
indicator

PST
indicator

Operation

indicator

(2-output type)

Channel select
switch (2-output type)