4-4 Display Settings (diSP)

4

Set

tings
f

o

r

Ad
v

an
ced F

u

nct
ion
s

4-28

- Digital Fiber Sensor FS-N10 Series User's Manual -

The saturation level can be set in the range of

100P

(100%) to

200P

(200%) when the

preset saturation function is ON.
For example, if this function is set to 150P, the received light intensity will be corrected
to "

150.0

" when the preset function is enabled, and the digital display will display

"

100.0

".

The saturation level can be set to a higher value for stable detection even in
environments which are prone to some contamination, such as dust.
Turn off this function if you want to display values above "

100.0

" in applications where

the preset function or the DATUM1 mode is used.

Setting too high of a saturation level (specifying too large a value)
decreases the detectability for small differences in light intensity or
transparent workpieces.

*1

When the detection mode is set to DATUM1, the preset saturation function ON/
OFF state can be selected, but the saturation level will be fixed to 101P (101%),
and the setting screen will not appear.

*2

When the detection mode is set to DATUM2, the preset saturation function set-
ting screen will not appear.

• For the preset execution method, refer to

"Preset Function" (page 3-6).

• Refer to the next page for the detailed operating principle.

Preset Saturation Function

Refer to page 4-2 "Display Settings (diSP)" for setting methods.

Display

Function

on

(ON)

Fixes the display to "

100.0

" (displays no value higher than "

100.0

")

when the actual received light intensity is above 100.0. (Default:

110P

)

oFF

(OFF)

Displays the actual received light intensity as is, even when it is
above "

100.0

".

Point