Full auto preset function, Enabling the full auto preset function, Full auto preset function -9 – KEYENCE FS-N10 Series User Manual

Page 31

Advertising
background image

3-3 Adjusting Sensitivity

3

Ba
sic
Oper

ati
on

3-9

- Digital Fiber Sensor FS-N10 Series User's Manual -

This function automatically judges 2 states (workpiece presence/absence, etc.), and
calibrates the current value to "

100.0

" and "

.0

".

This is useful when the detector is moving at high speed, etc.
* Not available for the FS-N10 Series shipped before March 10, 2011.

Enabling the full auto preset function

1

When the PST indicator is OFF, con-
tinue pressing the [PRESET] button
until "

Auto

" flashes while the work-

piece passes through.

2

After the workpiece has completely
passed through, release the [PRESET]
button.
Calibration is complete after the setting
value flashes momentarily, and then
stops (lights up).
The PST indicator lights in green, and the
setting value is set to "

50.0

".

• When the received light intensity is in a saturated condition (more

than the amount specified in "Display Gain" (page 4-32).), full-auto-
matic preset function is disabled. ("

---- ----

" will appear during

step 2.)

"Light emission/Received light intensity adjustment (Saturation

Canceling)" (page 3-18)

Full Auto Preset Function

Workpiece

Setting
value

MAX

MIN

Time

Receiv

ed

light intensity

The area near the maximum value
of the received light intensity while
the [PRESET] button is pressed is
set as "

100.0

", and the area near

the minimum value is set as "

.0

".

1

2

"

100.0

"

"

50.0

"

"

.0

"

Point

Advertising