The FS-N11MN is equipped with the analog voltage output function.
In the initial setting, voltage is output within the range of 1-5 V to the displayed
received light intensity of 0 to 4000.
The received light intensity corresponding to analog voltage of 5V can be changed
within the range stated below:

Setting range of received light intensity corresponding to 5V:

50

to

65535

* (Initial value:

4000

)

Setting range of received light intensity corresponding to 1V:

0

fixed (cannot be changed)

0

* The FS-N11MN shipped before March 10, 2011 becomes 100 - 9999.

• Received light intensity corrected with the preset function and

DATUM1/2 mode is not reflected in the analog output.

• When the work preset function, maximum sensitivity preset func-

tion or full automatic preset function is used, correction is made
so that the light intensity that becomes "

.0

" will correspond to the

analog voltage of 1V.

• While various preset functions are enabled, pressing the [PRESET]

button on the Analog Scaling Setting screen automatically sets
analog output scaling values so that 5V will be output to the cur-
rent value of "

100.0

".

• When the analog scaling mode setting is changed, the analog out-

put scaling values will be automatically set each time preset is per-
formed. (Correction by presetting is reflected in the analog output.)

"Analog output scaling (FS-N11MN only)" (page 4-21)

• Correction of the received light intensity using the zero shift

function is reflected in the analog output.

Analog output scaling (FS-N11MN only)

Refer to page 4-2 "Detection Settings (Func)" for setting methods.

50

1V

5V

Output voltage

4000 (Initial value)

65535

Received light intensity

Point