4-5 System Settings (SYS)

4

Set

tings
f

o

r

Ad
v

an
ced F

u

nct
ion
s

4-31

- Digital Fiber Sensor FS-N10 Series User's Manual -

Power consumption can be reduced by turning off the digital display and output
indicators.

Immediately after the ON or FULL option is selected, the option is enabled, and the
power save display results.
The normal display is restored after any key is operated (except for eco ALL).
If no operation is made for the next 30 seconds, the power save display returns.

When

FuLL

is selected, response time is 4 times as long as usual (i.e.,

as compared to when

oFF

or

on

is selected).

When

ALL

is selected, response time is the same as usual.



Deactivating eco ALL

1

Press and hold the [MODE] and [PRE-
SET] buttons simultaneously.

The screen returns to the display of cur-
rent received light intensity.
If no operation is made for the next 30 seconds, the eco ALL state is restored.

Power Save

Refer to page 4-2 "System Settings (SYS)" for setting methods.

Display

Function

oFF

(OFF)

Disables the power save function. (Default)

on

(ON)

Enables the power save function. (A single segment
pulses across the digital display.)

FuLL

(FULL)

Reduces power consumption. (The power save function is
ON, and response time is 4 times longer.)

ALL

(ALL)

Eco ALL (The digital display and output indicators are all
off).

This item becomes selectable by pressing and holding
while

FuLL

is lit.

The power consumption in Eco ALL is the same as that in
Eco ON.