4-3 Detection Settings (Func)

4

Set

tings
f

o

r

Ad
v

an
ced F

u

nct
ion
s

4-10

- Digital Fiber Sensor FS-N10 Series User's Manual -

• When the received light intensity stays lower than a given warning

level, the received light intensity correction stops and the DTM
indicator flashes.

"Changing the warning output level" (page 4-13)

• The light intensity correction stops if the raw received light inten-

sity drops below 50 (200 when the light intensity expansion setting
is set to

FuLL

). The raw received light intensity can be confirmed by

pressing the [MODE] button for longer than 3 seconds on the Basic
screen.

"Display Gain" (page 4-32)

• By pressing the [PRESET] button,

the current value (received light
intensity) can be forcibly calibrated
to "

100.0

". Calibration is completed

when the current value stops flash-
ing. (At this time, the setting value is internally calibrated so that the
received light intensity and setting value ratio stay constant.)

• You can also set the interval for executing correction, and/or the level of

received light intensity change for issuing a warning.

"Adjusting the correction interval" (page 4-12)

"Changing the warning output level" (page 4-13)

• The saturation level is fixed to 101P (101%). To display a value higher

than 100.0, turn the preset saturation function OFF.

"Preset Saturation Function" (page 4-28)