Fu n c tio n – Futaba 4PL 2.4GHz FHSS User Manual

Page 85

Advertising
background image

85

Fu
n

c

tio

n

Throttle neutral position

Dead Band

Point at which brakes

start taking effect

Position at which

motor star ts to
run

DBA-(DEAD BAND) ±2μs~±50μs

Same as Link software Dead Band.

This sets the range (neutral point range) over which the
ESC does not respond to transmitter throttle operation.

The larger the set value, the wider this range.

LBP-(LOW BATTERY VOLT) 2.5V~6V

2.5V~7.5V for MC950CR

Same as Link software Low Bat Protection

This setting cuts off the output to the motor when the
running battery voltage drops to the set voltage to
prevent the receiver from stopping operation when
the supply of voltage to the receiver becomes in suf-
ficient while running due to a drop in the power sup-
ply voltage. When the power supply voltage recovers,
power is supplied to the motor once more.

CTM-(C.L. TIME LIMIT) 50A~300A /CLT-(C.L. TIMER) 0sec(OFF)~240sec

(except MC950CR)

Same as Link software Current Limiter (Time Limit)/Current Limit timer.

The output current can be limited up to the set time lapse from the start of run-
ning. This is effective in preventing the motor from outputting wasted energy
when the voltage is high immediately after the power battery was recharged.

- "CTM" (Time Limit) sets the maximum output current within the time the out-
put current is limited.

- "CLT" sets the time the output current is limited. This function is disabled
when set to "0" sec.

Since the Current Limit Timer starts when the throttle is operated to the for-
ward side and current is output to the motor, this function begins to operate
when the motor is run during trim adjustment, etc.

100

50

0

%

Brake (Reverse) operation

Br
aking f

orce

Re
v

erse P

o

w

e

r

BMD-(BRAKE MAX DUTY) 0%~100%

Same as Link software Brake Max. Duty.

This setting can set the braking force between the neutral point and Max
brake point. The larger this value, the greater the braking force. When set
to "0%", the brakes are not effective.

RMD-(REVERSE MAX DUTY) w/back only 0%~100%

Same as Link software Reverse Max. Duty

This setting can set the reverse power between the neutral point and Max
reverse point. The larger this value, the greater the reverse power. When
set to "0%", the reverses are not effective.

100

50

0

Forward operation

Throttle response

FWB "50"

FWB "0"

FWB-(FORWARD BOOST) 0~100 (except MC850C)

Same as Link software Forward Boost

Operation near the throttle trigger (stick) neu-
tral position becomes a sharp rise.

MC950CR only setup item

REV-(REV CANCEL) BRk /REV

Same as Link software Reverse Cancel.

When set to BRk, reverse operation is not performed.

LA-(LEAD ANGLE) 0~1500

Same as Link software Lead Angle.

The lead angle of the motor can be set at the MC950CR side. However, we recommend that it
normally be set to "0". Since this setting is premised on setting by referring to the speed log by
the Link software, independent use of the MC LINK function of the T4PKS is recommended.

ESC Link Function "MCLNK"