Camber flp to ele, Model menu (airplane/glider functions), Setting method – Futaba 18MZ 2.4GHz User Manual

Page 122

Advertising
background image

122

<Model Menu (Airplane/Glider Functions)>

ELEVATOR

ELEVATOR 2

FLP 2

(Camber Flap)

FLP 1

(Camber Flap)

85%

CamberFLP to ELE

INH

OFF

POS

+0.0%

( +0%)

( +0%)

( +0%)

( +0%)

Linear

Separate

+100.0% +100.0%

Model 1

Condition 1

Gr.

+150

+100

+50

+0

-50

-150

-100

RATE

Rate A

+0.0%

Offset

Rate B

+0.0%

Fine Tuning

Single

NULL

+

0%

Rate 1

Rate 2

ELE

ELE2

+0%

+0%

+0%

+0%

● Mixing curve setting

● Fine tuning VR setting

●Return to Model Menu

Camber FLP to ELE

[Corresponding model type]: Airplane/glider, 2 ailerons + 1 flap or

more

This mixing is used to correct changes (elevator

direction) generated when the camber flaps (speed

flaps) are used.

● The elevator servo rates can be adjusted. When

the mix cause the servo direction to be reversed,

adjustments can be made by changing the

mixing rates at - to + (negative to positive).

● A mixing curve can be set.

● Mixing during flight can be turned ON/OFF by

setting a switch. (Always ON at "ON" setting)

● The mixing rate can be fine-tuned by setting a VR.

● Touch the [Camber FLP to ELE] button in

the Model Menu to call the setup screen

shown below.

*The display screen is an example. The actual screen

depends on the model type.

●Curve display mode switching

(Single/Fine tuning/All Cond.)

●Elevator rate adjustment

● Group/single mode switching

(Gr./Sngl)

● Overall

adjustment

by Rate A

and Rate B

Setting method

● Touch the ACT button and set the function to

ACT(ON).

● When setting a switch, touch the switch button

to call the <Switch> screen, and then select the

switch and set its ON direction. (Always ON at

"ON" setting)

● Touch the elevator servos left and right buttons

and adjust the mixing rate with the adjustment

buttons displayed on the screen.

*When the mixing direction is reversed due to linkage setup,

adjustments can be made by changing the rate value from +

to - (positive to negative).

● When setting a VR, touch the Fine tuning "NULL"

button to call the <Switch> screen, and then

select the VR.

The VR operation mode can be selected.

● A mixing curve can be set.

●The curve operation mode can be changed.

Single : Displays only the mixing curve

Fine Tuning : Displays the adjustment rate of the

fine tuning VR

All Cond. : Displays the mixing curve of all the

conditions (when conditions are set)

Advertising