CONTROLS and OUTPUTS

1. POWER ON switch.

Controls all power to the controller and all outputs. When power is
switched off, battery backed-up RAM preserves all internal totals and
parameters. All other functions are reset for normal start-up when
power is restored.

2. STOP END OF CYCLE / CONTINUE switch

This is the PREFERRED STOP switch. This switch is wired in series with

the level sensor. Turning it off breaks the signal to the computer the
same as covering the level sensor with material. This stops the
process at the end of a full cycle.

3. IMMEDIATE PAUSE / CONTINUE switch

Causes a computer-controlled immediate pause in the cycle. Dispenses
will stop in mid dispense if necessary. When switched back to

CONTINUE, the process continues without any error in amounts dispensed.

4. REGRIND thumbwheel switch (00 to 99)

This setting represents the PERCENT of the ENTIRE MIX that is to be
REGRIND.

A lower limit of 5% (05) has been entered into the software. This
limit may be altered using the keypad (see parameters, RLO).

A setting of "99" causes the system to run 100 percent regrind. With
this setting, no attempt is made to meter natural, color, or additive
unless the regrind dispense fills less than 1/2 of the weigh bin.

5. COLOR thumbwheel switch (00.0 to 99.9)

This setting represents the PERCENT of the NATURAL PORTION that is to
be COLOR. For example, if your COLOR to NATURAL mix ratio is 1:25 then

"04.0" is the proper setting. (1 pound of color to 25 pounds of
natural is 1/25 = 4%)

6. ADDITIVE thumbwheel switch (00.0 to 99.9)

This setting represents the PERCENT of the NATURAL PORTION that is to
be ADDITIVE. For example, if your ADDITIVE to NATURAL mix ratio is
1:100 then "01.0" is the proper setting (1/100 = 1%).