Conair WSB User Manual

Page 25

Advertising
background image

Detailed explanations are given on the pages that follow.

AUTOMATIC OPERATION MODE: (normal operation on power up)

These keys are operational in this mode.

VIEW: View Data: date, time, cycles, and lbs of Reg, Nat, Col, Add.
Press VIEW,* to print all data. At end press 00 to clear data.
RCP: Enter and retrieve stored RECIPES.
BTCH: Blend a preset weight, fill a container and stop. View/Enter
Target Wt., Cur. Portion, Total, Batch Count. CE=clear
FAST: Increase Output. Run rapid FAST cycles after a weighed cycle.
Press * to toggle this function on or off.
TAG: Tag a Work Order and Operator number to all reports.

EXIT: Operational in ALL MODES. Press to EXIT any and all sequences.
CE: Press to display the "raw signal" weight readout for 3 seconds.

MANUAL MODE: to enter press: "*" then (11111) or your own password.
These additional keys are operational.

SET: Observe current settings, set by thumbwheel or keypad.
OPER: Operate all devices manually; open and close valves.
TIME: Operate devices for a timed period.

CAL: Operate devices for a preset time period to learn the rate.
NOTE: With above four keys also press one DEVICE key:
NAT, REG, COL, ADD, DUMP, ALARM, MIX, or HOLD.
ZERO: Zero the tare weight with the bin empty.
FULL: With bin loaded, enter gram weight to calibrate load cells.

*00 Clear DATA fields.
*99 Enable calibration of load cells.

PROGRAM MODE: to enter press: "*" then (22222) or your own password.

MANUAL operations plus these additional keys are operational.

SET: Enter settings using keypad; locks out thumbwheel use.
PARA: View or change system constants and parameters.

STAR FUNCTIONS: Press * and two numbers for the following functions:

*02 Extrusion and Yield Control. *66 GB/WSB I.D. number (1-255).
*05 Inhibit table clearing. *69 Regrind as second natural.
*11 DATE - TIME, real-time clock. *71 Color percent of blend.

*12 Move table from ROM to RAM. *72 Additive percent of blend.
*23 Move from RAM to EEPROM. *74 Stop, alarm MAX wt exceeded.
*32 Move from EEPROM to RAM. *75 Alarm on weight drop.
*25 ROM OK flag, "CE" to clear. *77 Print parameters.
*33 Special Alarms. *78 Change program mode PASSWORD.
*44 End cycle - bin full. *82 Precision Ratioing.
*45 Change MANUAL mode password. *87 VOLUMETRIC operation.
*47 Totalizer flag. *88 Print display readout.
*52 Double dump weigh bin. *89 Select pounds, kilos.

*54 Print cycle information. *98 Display raw weight number.
*57 For Liquid Color PIAD system

Use "*" key to select readout or toggle flags ON or OFF.