SPECIAL TOTALIZER FUNCTION

A special function is available that allows throughput TOTALS to be

displayed at all times. This flag is for TOTALIZER models only.

When set, the display will continuously display the total amount of
material that has passed through the unit since the total fields were
last cleared. When the unit is functioning as a totalizer, this is
the information that is most meaningful.

Since totalizers do not blend, this flag also causes all settings to be
set to zero whenever power is turned on.

To reset the totals to zero:
First, stop operation by switching to "STOP END OF CYCLE".
Next, switch to "IMMEDIATE PAUSE".
Last, press "ALARM SILENCE" to clear the totals.

We may have already set this flag.
If we did not, the sequence of keystrokes is as follows:

+------------------------------------------------------+
¦ Press: * Display will say: (PASSWORD) ¦
¦ Press: 22222 Display will say: (P x.x) ¦
¦ Press: *47 Display will say: (BLENDER ) ¦
¦ Press: * Display will say: (TOTALIZE) ¦
¦ Press: EXIT Display will say: (P x.x) ¦

¦ Press: EXIT Display will say: ( x.x) ¦
+------------------------------------------------------+

This page to be replaced with the WIRING DIAGRAM pages