NOTE: Fractional cycles are not blended. Total weight may
be in over the target by as much as one cycle weight.

The EXIT key will exit the BTCH sequence at any point but

will NOT cause the system to start a new batch.

If an additional 120 volt output is desired for an alarm,
substitute a 4 or 7 for the 00001. 4 turns on the Additive
outlet, 7 turns on component 7 output.

If you have a printer connected, totals will print
automatically. (see VIEW, * for details).

FAST: This key will allow you to exceed the normal blending rate

of your unit. Once your system has learned proper flow
rates of each material, the timing of each component
dispense is very consistent cycle to cycle. The FAST key
allows one or more FAST REPEAT cycles to follow a normal
calibrated cycle. In a FAST REPEAT cycle all components are
dispensed simultaneously, without any weights being taken.
Errors in dispense amounts will not be detected. These are,
in fact, volumetric dispenses, not gravimetric. These
dispenses take much less time. Throughput may be doubled in

this manner.

This key is NOT FUNCTIONAL unless the 4th digit of the "FLG"
parameter is set to 1 (xxx1x). To do this, see the SOFTWARE
MAINTENANCE section, PARAMETER TABLE, "FLG".

The shorter mixing time may be a problem. So the number of
FAST REPEAT cycles is kept as low as possible. Up to 4
repeats may occur.

After pressing the FAST key, use the * key to toggle the
FAST flag ON of OFF. When set to (FAST OFF) FAST mode will
not operate. When set (FAST ON) every normal calibrated
dispense will be followed by up to 4 FAST repeat dispenses.

Press * to toggle between (FAST ON) and (FAST OFF).
Press EXIT, to exit.

When the FAST mode is in operation, the display ( FAST)
will flash intermittently.

TAG: This key (third row, third key) allows three pieces of
information to be "tagged" onto all data that is either
printed or retrieved through the computer port. The items
are WORK ORDER, OPERATOR, and RECIPE number.

This key is NOT FUNCTIONAL unless the 2nd digit of the "FLG"
parameter is set to 1 (x1xxx). To do this, see the SOFTWARE
MAINTENANCE section, PARAMETER TABLE, "FLG".

Press once to display the current Work Order number
(WO-----). Press again to display the current Operator
number (OPRTR---). Press again for the Recipe (RECP ---).
You may enter or change the Work Order or Operator number
when each is displayed. Recipe number can not be altered.