For this key to function, you must first set the weight
calibration flag ON. Press *99 to observe flag status.
Press * to toggle flag ON or OFF. With flag set ON, press

EXIT. Power-off always resets this flag to OFF.

Since the bin, even when empty, weighs about 1300 grams, it
is necessary on initial setup of equipment to instruct the
controller of the exact tare weight of the empty bin.

Slight drift in the tare or zero weight during day to day
operation is normal. All weight calculations automatically
compensate for this drift. However, when the bin is empty,
if the weight displayed is more than 50 grams above or below

zero, then you may wish to reset the electronics to display
zero when the bin is empty.

If, when the bin is empty, the weight displayed is greater
than 100, or less than -50, (Parameters TH and TL), the
dispense cycle will not begin. Instead, the dump valve will
repeatedly try to dump any material it thinks is in the bin
or will sound the alarm if weight is below -50. If the load
cell calibrations have drifted this far, it is absolutely

necessary to reset empty bin weight to zero.

If weight readings drift steadily in one direction, allow
system to warm up before setting ZERO or FULL weights.

Generally, when zero weight shifts, full weight reading
shifts the same amount. Since resetting ZERO WT
automatically shifts FULL WT the same amount, resetting ZERO
weight usually is all that is necessary to correct both ZERO
and FULL weights.

FULL WT: THIS HAS BEEN DONE AT THE FACTORY. IT SHOULD NOT BE
(FULL) NECESSARY FOR YOU TO DO THIS AGAIN.

ZERO WT. must be entered before FULL WT. to achieve proper
calibration. The FULL WT. key will not function until you
have set ZERO WT. as described above.

If you wish to reset the controller for proper full-weight
scale display, use any known weight as close to design full

weight as possible (1000, 2000, 4000, or 9000 grams). For
18000 gram systems, use 9000 grams. Place this weight in
the bin and press the FULL WT. key. The display will show
five dashes (FULL_____). Now enter the actual weight, in
grams, of the item you are weighing.

AGAIN, both FULL WT. and ZERO WT. have been set at the
factory. A drift of several grams from these settings is
normal and should not be of any concern. Recalibration

should be considered only if ZERO is more than 20 grams off
or FULL WT. is more than 50 grams off. These errors do not
prevent proper proportions from being dispensed. ZERO error
is always "tared" for proper weighing of each component.
FULL scale error will only cause accumulated totals to be
off by the degree of this error. The primary function of

Page 33