¦ PART I - ASSEMBLY ¦
+--------------------------------------------------------------------+

ASSEMBLY and INSTALLATION INSTRUCTIONS

CAUTION: LOAD CELLS ARE EASILY DAMAGED.
If the FRAME is dropped from TWO FEET, the load cells WILL be DAMAGED.
PLEASE, BE CAREFUL.

The following items have been shipped to you:

1. FRAME, fully assembled: (bolted to pallet)
2. CONTROLLER: the controller and the instruction manual.
3. FEEDERS: optional COLOR or ADDITIVE feeders as ordered.
4. FLOW CONTROL ASSEMBLY: optional
5. FLOOR STAND or VACUUM TAKEOFF ASSEMBLY: optional

RED INSTRUCTION STICKERS will assist you during assembly.

LIFT HANGERS are available to allow lifting of the blender with a strap
or chain. Call us if you require them.

1A. If your unit is to be MACHINE mounted:
For GB/WSB 100, 200, and 400 series models:
Two ways to do this are suggested ON THE NEXT PAGE.

The LEFT diagram shows the FRAME and SLIDE GATE both drilled
with the proper bolt pattern for your machine and THROUGH-
BOLTED to your press.

The RIGHT diagram shows only the 10 x 10 steel slide-gate plate
drilled for your bolt pattern and bolted to your press. The
FRAME is then bolted to it using the 8 x 8 inch bolt pattern
holes and bolts provided. With this method, bolt head
clearance holes are required in the poly-pro slide gate plate.
This mounting works well on smaller machines.

For GB/WSB 900 and 1800 series models:
An additional machine mount adaptor plate may be required. If

you have ANY DOUBT about the STABILITY of the unit when bolted
directly to your machine throat, please call us for advice.

NOTE: When choosing proper orientation, be sure you have access to
the controller and weigh chamber, clearance for hinged doors,
and access to removable feeder hoppers.

1B. If your unit is STAND mounted:
A stand is provided and your unit will bolt directly to it.

An assembly DIAGRAM is provided if stand assembly is required.

An air operated FLOW CONTROL ASSEMBLY is provided for dispensing
into a container. The purpose of this unit is to allow time for
mixing to occur after each dispense. This flow valve keeps the
mix chamber full to just below the sensor. This assembly bolts
directly to the bottom of the Blender frame.