Three (3) operation Modes are available; AUTOMATIC, MANUAL, PROGRAM.

KEYPAD - AUTOMATIC OPERATION MODE

This is the NORMAL operating mode. When power is turned on, the unit
is in this mode. Automatic dispensing occurs ONLY in this mode. The
AUTOMATIC mode is indicated by the ABSENCE of the letter "P" or "M" at
the left end of the display.

Only the VIEW, RECIPE, BATCH, FAST, TAG, *, CE, and EXIT keys are
available in this mode.
These keys operate BETWEEN cycles only or when the PAUSE switch is on.
To stop between cycles, use the "OFF AT END OF CYCLE" switch.

VIEW DATA: Press to display the CURRENT Date and Time, LAST CLEARED
(VIEW) date and time, and stored material usage data. Six totals
are available: (in Pounds, Kilos, Grams, or Ounces)

Number of CYCLES that have occurred: (CY= #####)
Weight of REGRIND that has been dispensed: (R = #####)
Weight of NATURAL: (N = #####)
Weight of COLOR: (C = #####)

Weight of ADDITIVE: (A = #####)
Total weight of ALL materials: (T = #####)

Each successive press of the VIEW key displays the next
total. The last displayed line will say (00=CLEAR) for 5
seconds. During this time, you may press 0,0 to clear the
data. Waiting 5 seconds or pressing any other key will exit
the sequence. When the sequence is exited, normal automatic
operation resumes. These totals may be displayed as pounds,
grams, kilograms, or ounces by a selection procedure

explained later (*89).

Press the VIEW key once followed by the "*" key to cause all
information to be sent to the printer (if available). To
then clear the data, press 00 within 5 seconds. Press any
other key or, wait 5 seconds, to continue the process
without clearing the totals.

RECIPE: This key allows you to LOOK at, RUN, and SAVE RECIPES.
(RCP) To SAVE a recipe you must be in the PROGRAM mode. Recipes

are thumbwheel switch settings. 100 recipes may be stored,
numbered 00 to 99.

This key is NOT FUNCTIONAL unless the 3rd digit of the "FLG"
parameter is set to 1 (xx1xx). To do this, see the SOFTWARE
MAINTENANCE section, PARAMETER TABLE, "FLG".

In normal Automatic mode: Press RCP key. If no RECIPE is
currently in use, display says (GET __). If a RECIPE is

currently in use then display will flash through the current
stored data:
(RCP __), (R = xx ), (C = xx.x), (A = xx.x)

Press CE to CLEAR CURRENT RECIPE and return to thumbwheels.

Page 27