Conair WSB User Manual

Page 67

Advertising
background image

PARAMETER DEFAULT SETTINGS - FOUR SOFTWARE

Here is a complete list of the "default" entries for all parameters as
they are provided in the original program, and as they will appear

after a CLEAR ALL or a model change.

The Model 220 list is the ORIGINAL BASE list.
Models 240, 140, MB, and 940 show only changes from the 220 list.
Models 1840, 420, and 440 show only further changes from the 940 list.
Models 131, 122 show only changes from the 140 list.

Base 3K ¦Base 10K
Model: 220 240 140 131 122 MB ¦ 940 1840 420 440
-----------------------------------------+-------------------------

FLG 00 ¦
¦
RPO 00 ¦
NPO 00 ¦
CPO 00 00101 00101 ¦
APO 00 00101 ¦
MPO 10 ¦
¦
RAL 00 ¦

NAL 04 ¦
CAL 04 ¦
AAL 04 ¦
¦
MIX 15 ¦ 30 99 15 15
JOG 3030 ¦
FCV 05 ¦
DTI 06 04 ¦ 06 08 10 10
¦
KDF 10 ¦ 02 04 02 02

WDF 10 ¦ 02 04 02 02
BER 1000 ¦ 200
¦
CXT 00 ¦
AXT 00 ¦
¦
ROC 00 ¦
ROV 00 ¦
RHL 00 ¦
¦

FUL 20000 10000 4000 ¦ 9000 18000 4000 4000
MAX 30000 15000 6000 ¦ 13500 27000 6000 6000
TH 1000 ¦ 1000 1000 200 200
TL 500 ¦ 500 500 100 100
¦
PRT 00 ¦
RSE 11000 ¦
CSE 11000 ¦
ASE 11000 ¦

RLO 50 ¦
¦
DLY 244 ¦
LT1 00 ¦
LT2 00 ¦
RPT 00 ¦