Conair WSB User Manual

Page 28

Advertising
background image

the ONLY way to CONTINUE OPERATION after a BATCH amount has
been run.

Assuming a proper "FLG" parameter is set:

Press the BTCH key once to view the desired BATCH WEIGHT.
Display will say (BW #####).
BATCH WEIGHT is the amount you wish to dispense before
stopping and/or sounding the alarm.

Press again to view the CURRENT PORTION, of the batch, that
has been dispensed.
Display will say (CP #####).
CURRENT PORTION shows how much has been blended so far.

Press again to view the ACCUMULATED TOTAL weight of all
batches dispensed.
Display will say (AT #####).
ACCUMULATED TOTAL is the sum weight of all batches that have
been blended. This number will continue to grow until it is
manually cleared to zero, or it exceeds its maximum possible
value.

Press again to view the total BATCH COUNT.

Display will say (BC #####).
BATCH COUNT is the total number of batches that have run.
This number will continue to grow until it is manually
cleared to zero, or it exceeds its maximum possible value.

Press again to return to normal operation.

When any of the above totals are being displayed, you may
press the CE key to RESET that number to zero. While all
four totals can be cleared to zero manually, only a BATCH

WEIGHT number can be entered manually.

When the BATCH WEIGHT is being displayed, you may enter a
NEW batch weight using the keypad. You must enter a 5 digit
number with leading zeros, if necessary. Maximum number
that can be entered is "59999".

The unit of weight that will be used is either POUNDS or
KILOGRAMS as determined by the *89 option, explained later.

While in operation, when the total is reached or exceeded,
the system will alarm and stop blending if the FLG parameter
is set to 00001. The system will alarm but CONTINUE running
if the FLG parameter is set to 00002.

Use the ALARM SILENCE button (on the side of the controller)
to silence the alarm. Pressing the BTCH key to view the
information will also silence the alarm.

If the system is programmed to STOP at the end of a batch,
the ALARM SILENCE button MUST be pressed to start blending
the next batch. The First press of the ALARM SILENCE button
will silence the alarm. The Second press will start the
next batch.

Page 29

Advertising