Conair WSB User Manual

Page 44

Advertising
background image

JOG 03030 Mix blade JOG count and interval

This parameter sets how many jogs will occur and how often.

FCV 00006 TIME the Flow Control valve delays before opening (sec.).

This parameter holds each batch in the mix chamber for a time to
assure mixing. This is only for units equipped with the optional
flow control valve under the mix chamber.

DTI 00006 Weigh bin dump TIME at end of cycle. (seconds)

This parameter sets the maximum open, or dump time for the weigh
bin. No change is required.

KDF 00010 Maximum variation in GRAMS between two consecutive weight
WDF 00010 readings for reading to be accepted. (x or x.x)

KDF controls sensitivity of weight readings during calibration of
load cells. No change is required.
WDF controls the sensitivity of weight readings during normal
operation. If excessive vibration interferes with weight
readings you may have to increase this number.

BER 00200 Excess GRAM weight before dispense is aborted.

This parameter controls sensitivity of the emergency "bailout"
routine that prevents overfilling of the weigh bin.
No change is required.

CXT 00000 Move decimal left on color and additive settings.
AXT 00000

These parameters allow entry of less then (00.1) percent for
COLOR or ADDITIVE.
When set to "00010" settings are read as X.XX percent.
When set to "00100" settings are read as .XXX percent.

ROC 00000 These three parameters help control regrind usage.
ROV 00000
RHL 00000

ROC indicates the PERCENT of REGRIND that will be treated as

natural when COLOR and ADDITIVE dispenses are calculated.
This adds some color or additive to your regrind.
ROV is for closed loop fully automatic reprocessing of regrind
scrap. This parameter will detect when more regrind is being
produced than consumed, and override the current setting to
use a higher amount. This helps prevent material backing up
in your grinder.
RHL has effect only if level sensors are added to your unit to
detect material level in the regrind hopper. These level

sensors can alter regrind percent usage.

FUL 20000 Full batch weight, determined by weigh bin size.
MAX 30000 Maximum GRAM weight the software will target.

FUL is the target weight that is blended each cycle. Change only

Page 45

Advertising