Conair WSB User Manual

Page 45

Advertising
background image

for extremely fluffy or very heavy material.
MAX prevents overflowing of the weigh bin. It is reset
automatically if the FUL parameter is changed.

TH 01000 The highest and lowest acceptable TARE weights for
TL 00500 blend cycle to start. (full or tenth grams)

TL prevents starting with the weigh bin out of place. No change
is required.
TH prevents starting with a full weigh bin. Change TH only if
clumps of material hang up in the weigh bin.

PRT 00000 MINUTE interval between automatic print of TOTALS.

This parameter will cause your system to PRINT MATERIAL TOTALS
automatically. A printer must be connected.

RSE 01000 Upper SETTING limits for thumbwheels (0xxx.x).
CSE 01000 Settings greater than limit are held to limit.
ASE 01000 "01000" = 100%.
RLO 00050 Lower SETTING limit for REGRIND (0xxx.x).

_SE parameters SET UPPER LIMITS to the thumbwheels. For color

and additive, lower settings may help ensure expensive
material is not wasted.
RLO sets a LOW limit of 5 percent to the REGRIND setting.

DLY 00488 Delay before cycle start. (interrupts)

This parameter is the time that the sensor must be uncovered
before a cycle will begin.

LT1 00000 Loader #1 time. (seconds)

LT2 00000 Loader #2 time.

These are timers for loaders. Since loader outputs are not yet
available, leave them set to zero.

RPT 00000 Percent of target to reduce first try dispense.
NPT 00000
CPT 00000
APT 00000

These can increase the accuracy of slow dispense devices ONLY,
like augers, and micro pulse valves.

RWT 26000 WT/TI = the rate that will be used for calculating the
RTI 00976 next dispense time.
NWT 26000 WT = the Weight portion of the dispense rate, calculated
NTI 00976 such that WT/TI equals the average of the last two
CWT 10240 actual dispense rates.
CTI 31232 TI = the TIME portion of the dispense rate. (interrupts)

AWT 10240
ATI 31232

These change AUTOMATICALLY during normal operation.
They are Weight and Time portions of the flow rate calibration.

Page 46