Conair WSB User Manual

Page 47

Advertising
background image

SCR 00000 Special Customer Request function to be activated.
BCR 00000 For BAR CODE input equipped blenders.

The following parameters are all related to EXTRUSION CONTROL only.

XTP 05050 Extrusion Control - TRIP POINT for a Rate adjustment.

As batch timing errors accumulate, this number determines how
large the accumulated error must be to force an adjustment.

XCV 00000 Extrusion Control - Extruder speed Control Voltage.
XRC 00004 Extrusion Control - Extruder speed Rate of Change.

These two paremeters control the voltage output to the extruder
speed control, and its rate of change.

TCV 00000 Extrusion Control - Takeoff speed control voltage.
TRC 00004 Extrusion Control - Takeoff speed Rate of Change.

These two paremeters control the voltage output to the downstream
takeoff speed control, and its rate of change.

XAL 00005 Extrusion Control - Single Adjustment Limit, percent.

Single rate adjustments are limited to this percentage change.

XUL 00200 Extrusion Control - Upper Adjustment Limit, volts

Adjustments beyond this voltage change will sound the alarm.

CPL Yield Control - Counts per unit Length.

Matches your down stream takeoff speed encoder to the software.

PTD 00020 Yield Control - Pulse Train Delta

Allows slight errors in encoder pulse train pulse rate

LIQ 00000 For LIQUID COLOR applications using dual pumps.

Allows automatic switching when current container runs out.

MCT 00000 Monitor Cycle Time

Alarms if normal cycle timing exceeds previous cycle time by a
specified amount. Used to detect mechanical failures.

Page 48

Advertising