_SE (This might be useful)

_SE is the upper SETTING limits for the thumbwheel switches. This
allows a reasonable cap to be set for each component so that an

operator cannot accidentally set the controls to an excessively high
setting. For color and additive, these limits will ensure that
expensive material is not wasted. Thumbwheel settings that are greater
than the limit are held to the limit.

EXAMPLE: If the highest color usage in your plant is 6%, you
may enter this upper limit in the parameter table. Since settings
are stored as 1/10s of percent (##.#), the parameter would be:
CSE 00060

Color thumbwheel settings above 060 will be held to 6 percent.

NOTE: If you wish to positively fix the settings so that the thumbwheel
switches have no control and no one can change them without
authorization, you may do this by using the KEYPAD to enter any or
all settings. To do so:
+---------------------------------------------------+
¦ Press: * Display will say: (PASSWORD) ¦

¦ Press: 22222 Display will say: (P x) ¦
¦ Press: SET Display will say: (SETTING ) ¦
¦ Press: COL (or ADD or REG) ¦
¦ Display will say: (C = xx.x) ¦
¦ Enter: New setting ¦
¦ ¦
¦ Press: EXIT Display will say: (P xxxxx) ¦
+---------------------------------------------------+

An LED will light indicating this override condition. This occurs

only when the thumbwheel does not match the internal setting.

To later return to thumbwheel control, use the same procedure as
above except instead of entering a setting, press the "CE" key
when you see the setting displayed.

The operator may still prevent running this component by entering
a setting of all ZEROS (00.0). This will override any setting
entered by the keypad. If you do not want this override option,
enter a 1 as the first digit in the SE parameter. (_SE 1xxxx)

======================================================================

RLO (probably no need to ever change this)

RLO is the lower limit for SETTING the regrind thumbwheel
switches. Settings lower than this number will be held to the low
limit. Air operated dump valves are not intended to dispense very
small quantities. We have set RLO at the factory to 5 percent (00050)
allowing a minimum dispense of 5% or about 100 grams.

======================================================================

DLY (consider changing if mixing is a problem)

DLY is the TIME the mix chamber level sensor must be uncovered
before a cycle begins. The sensor must be uncovered without

Page 58