*57 For LIQUID COLOR applications only. This function usually
operates in conjunction with an additional two air solenoids
mounted on the blender frame.

Press (*,5,7) to allow automatic switch over to a full drum
when the current drum of color runs out. When function is
off, display will say (COL= 4 ). Press * to toggle to (COL=
4+7). When display says (COL= 4 ), the color setting aplies
to output 4 only, the standard COLOR output. When display
says (COL= 4+7), this means that output 4 is the starting
output, and when no weight is detected after a dispense, the
output switches to output 7. The "7" is determined by the
parameter (LIQ 00007). You can change the secondary output
by changing the parameter.

If output 7 is also empty, the output switches back to 4.
See parameter (LIQ 00007) for more information.

*66 Press (*,6,6) to enter an identification number for this
particular weigh scale blender. This I.D. number will appear
on all printed reports. If you have more than one unit, this
helps to identify reports. If you are using a computer to
automatically gather data, then each controller must have a

unique address. Valid numbers are 000 to 255. They need not
be consecutive. When units are connected to a computer, do
not use the number 000 for identification.

*69 Press (*,6,9) to set flag to treat the "REGRIND" dispense as
a SECOND NATURAL material.

With the flag OFF, Natural is calculated to fill the space
remaining in the weigh bin after a Regrind dispense has
occurred. In other words, when a reduced amount of Regrind

is dispensed, additional Natural is dispensed. Color and
Additive dispenses are calculated as a percentage of this
Natural dispense ONLY.

With the flag ON, Natural is calculated to maintain the
proper RATIO between the two components (Natural and
Regrind). Color and Additive dispenses are calculated to
add to BOTH components at the requested ratios.

"Regrind", in the normal sense, is not added. Instead, this

component is treated as another "Natural" material. If the
ratio of the two naturals is not 50/50, place the HIGHER
volume component in the "regrind" side. Set the "regrind"
thumbwheel for the percentage that the "regrind" side is of
the combined mix. For example; Naturals A and B are to be
used at a 20/80 mix ratio; B is the greater at 80 percent.
Put component B in the regrind side and set the regrind
switch for 80 percent.

NOTE: The Regrind alarm parameter (RAL) is automatically
set to a number that forces retries and stops the system
when this component runs out. See PARAMETERS, RAL-00004.

Use the * key to toggle flag ON or OFF.
Press EXIT when desired flag status is displayed.