select Modify. The following prompt box will appear with a flashing cursor at the first entry of the
table.

The Reader Name A entry allows you to define a short description for that reader; in this
application it is the employee entrance. Type:

EMP ENTRANCE

Use your pointing device and select the Reader Name B entry. The Reader Name B entry is used
when you have two reader antennas attached to the same control unit to control both entrance
and egress. This is true for this example. For Reader Name B, type:

EMP EXIT

This allows you to keep track of when an employee’s access card entered or exited through this
door.

NOTE: There is a 16 character maximum for the Reader Name description. Please use
short names or descriptive abbreviations when entering reader names.

The Open time is the number of seconds a door may be held open for entrance or egress before
an alarm event is generated. The software default is 20 seconds, but we will allow an employee
40 seconds to use the door before an alarm event is generated. Use your pointing device and
select the Open time. Type:

40

The Unlock time is the number of seconds the control unit holds the lock relay open – essentially
the amount of time that an access control door will be held unlocked beginning from when an
access control card is presented to the reader. The software default is 5 seconds, but we will
have the control unit hold the lock relay open for 15 seconds. Use your pointing device and select
the Unlock time. Type:

15

The next entry defines if local APB (versus network APB) is enabled. APB stands for anti-
passback. This feature is used to ensure one-card/one-way access into and then out of a
controlled area. For local APB, an authorized card presented to an access reader will allow
access, but will not work again for access until presented to the egress reader, or until either the
control unit is reset with the anti-passback amnesty command (see the anti-pass back amnesty

Modifying Reader 4

Reader Name A
Reader Name B
Open time (seconds) 20
Unlock time (seconds) 5
Local APB enabled (Y/N) N
Auto-Unlock time zone 1 07
Auto-Unlock time zone 2 07
Supervised I/O (Y/N) N
Alarm Control (Y/N) N
Input Normal Polarity (O/C) C

Press ENTER to accept, ESC to abort