Keri Systems TAP100 User Manual

Page 44

Advertising
background image

TAP 100 Application Software Manual

Page 44

Revision 3.3

Use the up and down arrows to select the links you wish to define. In this example, we will work
with I/O assignment link 3. We will use inputs 3 and 4 and we will use output 2 on reader 3.

Use the up and down arrows and place the highlight bar on link 3. Use your pointing device and
select MODIFY. The following prompt box will appear.

There are five fields you will need to work through to make the I/O assignment. If at any time
during the assignment process you wish to exit without making any changes, use your pointing
device and select QUIT. If at any time you wish to return all inputs and outputs to their factory
default values (all inputs and outputs disabled), use your pointing device and select DISABLE.

The first field to define is the Input Reader field. This field defines which reader the input signal is
coming from. Use your pointing device and select the Input Reader field. The following prompt
box will appear.

To exit without selecting a reader, use your pointing device and select QUIT. For this example,
use your pointing device and select Reader 3, then select OK.

The second field to define is the Input Lines field. This field defines which of the 4 available inputs
at the reader is being assigned to this link. The factory default for all inputs is to set the input to
None. The input line can be defined in one of two ways: Active or Normal. A normal input is an
unsupervised 2-state input. An active input is a supervised 3- or 4-state input.

I/O ASSIGNMENTS FOR LINK 3

Input Reader:

Sup I/O: No

Polarity: Norm. Closed

Input Lines:

1
2
3
4

Output Reader:
Output Lines:

1
2

1 Reader 1

( ) Active ( ) Normal ( ) Tamper ( ) None
( ) Active ( ) Normal ( ) Tamper ( ) None
( ) Active ( ) Normal ( ) Tamper ( ) None
( ) Active ( ) Normal ( ) Tamper ( ) None

[ X ] Send to PC

1 Reader 1

( ) Not Used ( ) Deactivate ( ) Activate ( ) Momentary
( ) Not Used ( ) Deactivate ( ) Activate ( ) Momentary

OK

QUIT

DISABLE

Select A Reader

Choose an Input Reader
OK/ENTER accepts, QUIT/ESC cancels.

All

2

Reader 2

3

Reader 3

• • •

OK

QUIT

1

Reader 1

Advertising