Keri Systems TAP100 User Manual

Page 45

Advertising
background image

TAP100 Application Software Manual

Revision 3.3

Page 45

NOTE: The Tamper value is used by the control unit itself. It is designed to be connected
to a tamper switch on the enclosure protecting the control unit. This allows you to define
an input to indicating if an individual is attempting to tamper with the control unit.

In this example, use your pointing device and select Normal on Input Lines 3 and 4. All other
inputs should be set to None.

The third field to define is the Output Reader field. This field defines which reader the output
signal is going to. Use your pointing device and select the Output Reader field.

To exit without selecting a reader, use your pointing device and select QUIT. For this example,
use your pointing device and select Reader 3, then select OK.

The fourth field defines if an event on the input should be recorded in the transactions log. Before
deciding, note that whenever an output is triggered (by an input signal) the output is always
reported in the transactions log. If you wish to have the redundancy of reporting the input that
triggered the output, as well as reporting the output, use your pointing device and select Send to
PC. For this example, we want to report input events, so use your pointing device and select
Send to PC.

The fifth field to define is the Output Lines field. This field defines which of the 2 available outputs
at the reader is being assigned to this link. The factory default for both outputs is set to Not Used.
The handling of the output line can be defined in one of three ways: Deactivate, Activate, or
Momentary. Deactivating the output sets the output relay to its inactive state. Activating the output
sets the output relay to its active state. Setting the output to Momentary will cause the output to
momentarily toggle its state. For this example, we want to toggle the output, so use your pointing
device and select Momentary for output 2.

After all of these changes have been made, the I/O Assignments for Link 3 prompt box should
appear as follows.

Select A Reader

Choose an Output Reader
OK/ENTER accepts, QUIT/ESC cancels.

All

2

Reader 2

3

Reader 3

• • •

OK

QUIT

1

Reader 1

Advertising