Setting an ‘and’ i/o assignment – Keri Systems TAP100 User Manual

Page 43

Advertising
background image

TAP100 Application Software Manual

Revision 3.3

Page 43

TAP-100 VERSION X.XX I/O Assignments
DATE TIME page #
==========================================================

INPUT

INPUTS

OUTPUT

OUTPUTS

LINK READER

1

2

3

4

PC

READER

1

2

0

Reader 1 (01)

N –

PC

Reader 2 (02)

M

1

Reader 2 (02)

N –

PC

Reader 2 (02)

M

• • •

31

-----Available -----

After reviewing this information, if you are not satisfied with a link entry, you must use the up and
down arrow keys and select the link that needs changing. Once you have selected the link that
needs changing, you have two options: you can edit the existing link, making the necessary
corrections, or you can use your pointing device and select DISABLE, returning all inputs and
outputs to the factory default disabled settings.

Once you are satisfied that all I/O assignments are correct, you must send this information to all
control units on the network for it to take effect. Use your pointing device and select SEND. The
Status Message Line will display:

Once communication is established, the information is transferred to the network. Each reader
will beep twice, acknowledging they have received their data.

In this case, the result of these changes is that an input signal on the first input of either Reader 1
OR Reader 2 will create an output signal on the first output of reader 2.

Setting an ‘AND’ I/O Assignment

To set-up the required input to output links for an ‘AND’ connection, use your pointing device and
select Utilities and then I/O Assignments. Adding to the previous example for an ‘OR’ assignment,
the following prompt box will appear.

In an ‘AND’ connection, you will use one I/O assignment link for all inputs to be ‘AND-ed’ together
(these inputs must reside on the same option board). All of these links will be assigned to the
same output on the same controller.

NOTE: To keep the hardware and software interface as simple as possible, and continue
to support both ‘OR’ and ‘AND’ logical functions, ‘AND-ing’ is limited to the inputs residing
on one controller.

Initiating communication with local network on COM1 . . . please wait.

I/O ASSIGNMENTS

INPUT

INPUTS

OUTPUT

OUTPUTS

LINK

READER

1

2

3

4

PC

READER

1 2

1

Reader 2 (01)

N

PC

Reader 2 (02)

M

2

-----Available -----

3

-----Available -----

• • •

0

Reader 1 (01)

N

PC

Reader 2 (02)

M

MODIFY

PRINT

SEND

CLEAR

QUIT