Removing and replacing the current user interface – LAARS NeoTherm NTV (Sizes 399-850 MBTU/h) - Service Manual User Manual

Page 95

Advertising
background image

85

Service Manual - NeoTherm 500

Removing and Replacing the Current User Interface

Fig. D7-1 - Current user interface

Tools and equipment required:
* Soft cloth (clean towel, etc.)
• Small Phillips-head screwdriver (size #1)
Procedure
1. Turn off power to the system. Use the main discon-

nect switch mounted above the front panel.

2. Place the soft cloth on top of the NT unit.
3. Pull the upper front panel outward. Grip the two

handles, and pull straight out. Once the panel is

free, handle it carefully, because the wires will still

be connected. Swing the panel up and place it, face

down, on the cloth.

Ribbon cable

connectors

X01 -

12-pin

X07 -

8-pin

4. Disconnect the two wiring connectors:

• 8-pin connector

X07

• 12-pin connector

X01

Each connector is held in place by a locking tab. To

release the connector, push the tab down.

5. Disconnect the two ribbon-cable connectors.
6. Remove the four Phillips-head screws and separate

the user interface board from the back of the front

control panel.

7. Below the circuit board you will see the button actua-

tor. This is a small soft plastic part that is part of the

button assembly. Be sure this part remains in the

position shown in the photo.

Fig. D7-2 - Removing the connectors

Fig. D7-3 - Placing the button actuator

D7

Advertising
This manual is related to the following products: