22

[Rear]

3

4

5

6

7

8

9 10

11

3. DC Power Input Terminal

Connect this terminal to 24 V DC power supply.
Power is supplied from the FS-7000PS.
(M3 screw terminal; barrier distance: 6.4 mm)

4. GM Group Control Terminals

Connect these terminals to the FS-7000GM.
Output is provided when zones are selected using
the FS-7000RM's zone selector keys programmed
to function as group selector keys.

5. GM Zone Control Terminals

Connect these terminals to the FS-7000GM.
Broadcast zones included in the group selected
via the FS-7000RM's keys designated as group
selector keys are individually input by the FS-
7000GM.

6. Functional Earth Terminal

Connect this terminal to the functional earth
terminal of external equipment if excessive noise
is generated when the external equipment is
connected to the FS-7000RF. This could reduce
noise.
Note: This terminal is not for protective earth.

7. Function Switch

This switch performs the following settings:
• FS-7000RM all-zone call mode (SW #1)
Sets the mode of broadcast selected with the FS-
7000RM's all-zone call key to Normal or Urgency.
• Number of FS-7000RM units (SW #2 and #3)
Sets the number of FS-7000RM units to 1 through
4.

• Number of system's broadcast zones (SW
#4~#6)
Sets the number of zones to 10 through 50 in 10-
zone units.
• Priorities among FS-7000RM units (SW #7 and
#8)
Sets priorities among the FS-7000RM units to
"None," "Last-In-First-Out," "First-In-First-Out," or
"Individual."
(Default: "Normal," "1," "10 zones," and "Last-In-
First-Out")

8. FS-7000RM Link Terminals

The following terminals are available for
connection of the FS-7000RM:
• AUDIO
Connects the audio line from the FS-7000RM.
• DC 24 V
Supplies 24 V DC power to the FS-7000RM.
• BUS
Communicates data with the FS-7000RM.
(M3.5 screw terminal; barrier distance: 7.2 mm)

9. RF Zone Control Terminals

Connect these terminals to the FS-7000CP
and/or FS-7010CP. Data of zones selected via
the FS-7000RM is output from these terminals.

10. RF Control Terminal

Connect this terminal to the FS-7000CP

11. RF Audio Output Terminal

Connect this terminal to the FS-7000CP. Audio
signals from the FS-7000RM are output.

Advertising