Symptom

Possible Cause

Check/Remedy

Output is not being provided correctly
because of a short in the output wiring.

FS-7006PA's or
FS-7012PA's Fault
indicator lights.

Remove the output wiring and turn the
power on again. If the Fault indicator light
goes out, then the problem may be with
the wiring. Check the wiring to determine
where the problem may be.

If the indicator light does not go out, or if it
goes out but then lights again within a
short period of time, consider whether the
following may be the problem:

Equipment failure or excessive high
heat build-up inside the unit.

YA-7000's Operation Mode Selector
switch was set to "Test" during its
installation.

Check the following points if the indicator
automatically goes out within 30 minutes
after it has lit.

Check installation conditions for
appropriate ventilation.

• Check the connected load capacity for

possible overload.

• Check to see if input and output cables

are installed close to each other.

If all of the above are found to be in
correct working order, then it is likely that
the equipment itself is malfunctioning in
some way.
Equipment failures can also be considered
if the indicator lights again within a short
period of time even if it has gone out once.
Request maintenance and repair action.

Set the mode switch to "Normal."