Toa FS-7000 SERIES Installation User Manual

Page 74

Advertising
background image

74

Step 6. Connect the FS-7000GM unit to its circuit board using the supplied connector-equipped cables.

Connect one end of the cable to CN301 on the FS-7000GM circuit board and insert the other cable
end into the rear panel-mounted connector receptacle opening for "GM ZONE CONT 1" (indicated on
the rear panel).
Similarly, connect the other cables to CN302 and "GM ZONE CONT 2," CN303 and "GM ZONE
CONT 3," CN304 and "GM ZONE CONT 4," and CN305 and "GM ZONE CONT 5."
Then, insert the cables affixed to the FS-7000GM's bottom surface with tape into CN101 and CN202
on the circuit board. The CN101 connects to CN4 on the circuit board already mounted in the FS-
7000GM unit, while the CN202 connects to CN9 (refer to the internal wiring diagram).

1

2

3

4

5

CN4

CN101

CN301

CN302

CN303

CN304

CN305

CN202

CN9

Note the connector's correct
insertion orientation.

Polarizing guide

Connector

Rear panel opening
(as viewed from the inside)

Insert the connector fully.

Rear panel

Toward internal circuit board

GM Zone Control terminals

FS-7000GM internal wiring diagram

Step 7. Replace the case after installation has been completed.

Note
Take care not to pinch cables when replacing the case.

Advertising